Your basket is currently empty!
SKC Parallel Particle Impactors (PPIs) – 8 Litre/min.  HIRE Kit containing 4 off PPIs and a calibrator. These Parallel Particle Impactors (PPIs) are high performance, reusable Thoracic and Respirable PM Samplers. Each unit has the power of 4 standard respirable sampling heads in one small, conductive aluminium sampler. It provides the closest match to…
 HIRE Kit containing 4 off PPIs and a calibrator.
These Parallel Particle Impactors (PPIs) are high performance, reusable Thoracic and Respirable PM Samplers.
Each unit has the power of 4 standard respirable sampling heads in one small, conductive aluminium sampler. It provides the closest match to the ACGIH/ISO/CEN thoracic or respirable conventions.
A full descriptive leaflet can be downloaded:- SKC Leaflet
Disposable pre-oiled porous Plastic Impaction Substrates reduce the negative effects that particle buildup and bounce can have on the sample accuracy, by firmly trapping larger particles.
Unlike other samplers, the sampling efficiency of the PPI is not dependent on the collected particle type.
Note
50 pre-oiled Impaction Substrates are provided with Hire Kit – 4 required for each sample head/sample collected.Â
If you require more Disposable Substrates – you may purchase additional Substrates here:-Â Â Pack 50 Pre-Oiled Disposable Substrates
Parallel Particle Impactor (PPI) samplers contain four small impactors in the inlet section of the device (see diagram below).
Each impactor features a unique 50% cut-point to target a specific one-quarter segment of the ISO/CEN curve resulting in a precise fit along the entire curve.
Sample pumps (Casella Vortex3 8l/min) are also available for Hire) here:-Â Â Casella 5 – 12l/min Sampling Pumps for HIre
The sampling pump pulls air through the inlet nozzle of each impactor in the inlet plate. Particles larger than each impactor’s 50% cut-point are scrubbed and retained on the porous oiled impaction substrate, while smaller particles continue to the standard 37 mm collection filter for analysis.
The kit also contains a DryCal primary calibrator (or equivalent). The DryCal DC-Lite offers a primary flow standard that can be used for accurate calibration of the air sampling pumps. Displays flow rate, flow average with number of readings – no fiddling with rotameters.
Pre-weighed 37mm collection filters are available from IOM Consulting Limited, Research Avenue North, Riccarton, Edinburgh EH14 4AP; Tel 0131 449 8059.Â
Note:- Hirer is responsible for return carriage costs however a Pre-Paid Return Courier option is available (see below under ‘Returns’)
Note: The hire equipment does not include collection media (such as the pre-weighed filters) or analysis of collected samples. We can provide guidance on these items and labs for analysis if required.
ON RECEIPT
RETURNS
This item – Available for hire to UK addresses only
SKC Hi Flo Sampling Heads | Kit of 5 PPI Heads |
---|